Sigma SQC-122c manual Chapter Quick Start Rear Panel, Power Input Fuse

Page 8

Chapter 1

Quick Start

1.3Rear Panel

Manufactured By

SQC-122c Deposition Controller

S i g m a

Serial No.

? instruments

 

Sensor 3 Sensor 4

Output 3 Output 4

 

I/O 9-16

 

 

 

 

 

 

 

 

 

 

Sensor 1 Sensor 2

Output 1 Output 2

I/O 1-8

 

 

 

100-120/200-240 V~

5 0 / 6 0 H z

25 VA

Fuse T . 5A 250V

R S - 2 3 2

Sensor 1 & 2

Output 1 & 2

I/O (1-8)

RS-232

Sensor 3 & 4

Output 3 & 4

I/O 9-16

Rear Panel Connections

Connects to quartz crystal sensor remote oscillator.

Connects the SQC-122c output to your evaporation supply control input.

Connects 8 relays and 8 digital inputs to external equipment for process control. See Appendix C for connections.

Connects to computer for programming and data acquisition.

This option card is available only on SQC-222 controllers. Contact Sigma for upgrade information.

Measurement ground terminal useful for common system and cable grounding.

Power Input and

WARNING: For continued protection, replace fuses with the

Fuse

proper type and rating.

 

WARNING: Use removable power cords only of the specified

 

type and rating, attached to a properly grounded receptacle.

1-3

Image 8
Contents SQC-122c Thin Film Deposition Controller User’s Guide Safety Information Safety SymbolsReturn Policy Warranty InformationLimitation of Warranty Table of Contents Chapter Quick Start Chapter OperationChapter Menus Chapter OptionsAppendix Chapter Quick Start Introduction Thin Film Process OverviewChapter Quick Start Front Panel Power Input Fuse Chapter Quick Start Rear PanelChapter Quick Start System Connections Chapter Quick Start Installation Chapter Quick Start Process Setup PowerQuick Setup SelectExit to Main Edit Mode LayerChapter Quick Start Chapter Quick Start Depositing a Film This page left blank for your notes Defining a Film Chapter Operation IntroductionDefinitions POWER% POWER% Deposition Controls Menu Chapter Operation Defining a Process Layer Edit MenuChapter Operation Chapter Operation Sensor Setup Tooling U n d e r 1 0 0 % Chapter Operation Chapter Operation Source Setup Chapter Operation Running a Process Chapter Operation Next Menu Zero THICKNESSkA RATEA/s 824 55.3 Chapter Operation Loop Tuning Chapter Operation Chapter Operation Troubleshooting No Readings, or Erratic Readings from SensorsIncorrect Rate or Thickness Measurement Poor Rate StabilityThis page left blank for your notes Chapter Menus Introduction Default, power-up Main Screen display is shown below Chapter Menus Main MenuSetup NextMenu Quick FilmChapter Menus Next Menu Screens Chapter Menus Quick Setup Menu Exit to Main EditPrev Layer Next LayerChapter Menus Chapter Menus Process Menus Main Screen Prev Menu Select Edit Delete Control KnobMain Screen Prev Menu Edit Cut Paste Insert Layer Control KnobPOWER% Exit to Main Prev Menu Edit Control KnobChapter Menus Chapter Menus Film Menus Main Screen Prev Menu Edit Delete Control KnobExit to Main Prev Menu Edit Exit to Main Prev Menu Edit THICKNESSkA RATEA/s Deposition Controls Menu Chapter Menus Chapter Menus Chapter Menus Chapter Menus System Parameters Menu Chapter Menus Chapter Menus Chapter Menus I/O Setup Mapping MenuRelays Explanation closes when Inputs Explanation high input causesThis page left blank for your notes Option Card Full Rack Extender InstallationChapter Options Introduction Appendix Material Parameters Appendix Specifications General SpecificationsMeasurement SourceDisplay Appendix O Connections Connector Wiring Relay PinsInput Pins Appendix Appendix Handheld Remote Controller Complies with the Essential Health and Safety Requirements Appendix EC Declaration of ConformityDeclares that the product Uses the following standards