Chapter 2 - Configuring HDSL Parameters

CONFIGURING HDSL ALARMS

You can configure options for four types of alarms:

HDSL ES Alarm Threshold determines the number of errored seconds that must occur to trigger an alarm.

HDSL Margin Alarm Threshold determines the margin, in dB, that triggers an alarm.

Alarm on Local I/F LOS lets you enable or disable the local Loss of Signal alarm.

Alarm on Remote I/F LOS lets you enable or disable the remote Loss of Signal alarm.

Access the configuration screen, then set the options.

Accessing HDSL Alarms Configuration

1From the Main Menu (page 14), type 3 then press ENTER to access the System Settings Menu.

Jul 07,

2003

ADC TELECOMMUNICATIONS, CAMPUS RS, Version

5.1 08:19:34

Local Unit ID:

Local I/F:

REX2

Remote Unit ID:

Remote I/F: REX2

Circuit

ID:

 

 

SYSTEM SETTINGS MENU

1)SYSTEM PARAMETERS

2)HDSL PARAMETERS

(R)eturn

ENTER CHOICE>