Chapter 5 - Monitoring and Testing the Campus System

Viewing Local Alarm History

This screen displays alarm history information. From the System Status Menu, type 4 then press ENTER . The Local Alarm History screen is displayed.

Jul 07, 2003

ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34

 

Local Unit ID:

 

 

 

Local I/F: REX2

 

Remote Unit ID: Inactive

 

 

Remote I/F: Inactive

 

Circuit ID:

 

 

 

 

 

 

 

 

 

LOCAL ALARM HISTORY

 

 

Type

 

Current

First

Last

Count

HDSL Link,

ACTIVE

Dec 09, 1999-04:30:03

Nov 31, 1999-12:21:01

1

ES,

HDSL-A

OFF

 

 

 

0

ES,

HDSL-B

OFF

 

 

 

0

Margin, HDSL-A

OFF

 

 

 

0

Margin,

HDSL-B

OFF

 

 

 

0

LOS,

Port

OFF

 

 

 

0

Last Cleared:

None

 

 

 

 

 

 

(S)witch to Remote Alarm History

 

 

 

 

(U)pdate

(C)lear

 

 

 

 

 

(R)eturn

(M)ain Menu

 

 

ENTER CHOICE>

 

 

 

 

 

 

This screen shows alarm history of the local unit. If the HDSL line uses two loops, the screen includes information for both loops. The screen includes information on the following alarms:

Errored seconds (ES) for HDSL loop A (first pair) and HDSL loop B (second pair, when applicable)

Margin for HDSL loop A (first pair) and HDSL loop B (second pair, when applicable)

Loss of Signal (LOS) for the HDSL port

To view remote alarm history, type S then press ENTER .

To update the information, type U then press ENTER .

To clear the information, type C then press ENTER .

Alarm history information is lost when power is removed from the Campus unit.

Campus-REX2 RS Interface Card User Manual

79