Chapter 5 - Monitoring and Testing the Campus System
Viewing Local Alarm History
This screen displays alarm history information. From the System Status Menu, type 4 then press ENTER . The Local Alarm History screen is displayed.
Jul 07, 2003 | ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34 |
| ||||
Local Unit ID: |
|
|
| Local I/F: REX2 |
| |
Remote Unit ID: Inactive |
|
| Remote I/F: Inactive |
| ||
Circuit ID: |
|
|
|
|
|
|
|
|
| LOCAL ALARM HISTORY |
|
| |
Type |
| Current | First | Last | Count | |
HDSL Link, | ACTIVE | Dec 09, | Nov 31, | 1 | ||
ES, | OFF |
|
|
| 0 | |
ES, | OFF |
|
|
| 0 | |
Margin, | OFF |
|
|
| 0 | |
Margin, | OFF |
|
|
| 0 | |
LOS, | Port | OFF |
|
|
| 0 |
Last Cleared: | None |
|
|
|
| |
|
| (S)witch to Remote Alarm History |
| |||
|
|
| (U)pdate | (C)lear |
|
|
|
|
| (R)eturn | (M)ain Menu |
|
|
ENTER CHOICE> |
|
|
|
|
|
|
This screen shows alarm history of the local unit. If the HDSL line uses two loops, the screen includes information for both loops. The screen includes information on the following alarms:
•Errored seconds (ES) for HDSL loop A (first pair) and HDSL loop B (second pair, when applicable)
•Margin for HDSL loop A (first pair) and HDSL loop B (second pair, when applicable)
•Loss of Signal (LOS) for the HDSL port
To view remote alarm history, type S then press ENTER .
To update the information, type U then press ENTER .
To clear the information, type C then press ENTER .
Alarm history information is lost when power is removed from the Campus unit.
79 |