Chapter 3 - Configuring the REX2
2For the REX2 Configuration and Status screen, type 6 then press ENTER . The SNMP Configuration screen is displayed.
Jan 01, | 1970 | ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 | 18:05:29 |
Local Unit ID: | Local I/F: REX2 |
| |
Remote Unit ID: | Remote I/F: REX |
| |
Circuit | ID: |
|
|
SNMP CONFIGURATION
1)Unit Name:
2)Location:
3)Contact:
4)SNMP Read Only Community String: public
5)SNMP Read/Write Community String: private
6) | Authentication Trap Status: | Enabled | (Enabled, Disabled) |
7) | Trap Receiver 1 IP Address: | 0. 0. 0. | 0 |
8)Trap Receiver 1 Community String: trap receiver 1
9) Trap Receiver 2 IP Address: | 0. 0. 0. 0 |
10)Trap Receiver 2 Community String: trap receiver 2
11) Trap Receiver 3 IP Address: | 0. 0. 0. 0 |
12)Trap Receiver 3 Community String: trap receiver 3
(R)eturn (M)ain Menu
ENTER CHOICE>
3Continue with the following sections to enter the required parameters and enable authentication error trap generation.
Entering SNMP Parameters
On this screen, you configure parameters that identify this
•SNMP Read Only Community String provides the authentication string used for SNMP
•SNMP Read Write Community String provides the authentication string used for SNMP
To set SNMP parameters, enter the following information on the SNMP Configuration screen.
1To enter a Unit Name, type 1 then press ENTER . At the prompt, enter up to 32 characters (use any ASCII character) that identifies for SNMP management this Campus unit.
Maximum length is 32 characters.
Enter Unit Name: REX2_Southall
61 |