Chapter 4: Troubleshooting

FLT LED is Steadily ON

LK LED is OFF

If the converter FLT LED is steadily on, a problem has occurred in the converter, perform the following:

ˆTry resetting the converter by disconnecting and reconnecting the AC power cord.

ˆTry resetting the management card by pressing the reset button on the LED interface card with the tip of a pen or a non-conductive pointy object.

ˆTry resetting the line card or the module installed in the rear expansion slot by pressing the reset button on the LED interface card with the tip of a pen or a non-conductive pointy object.

Note

If the FLT LED remains steadily on, contact Allied Telesis Technical Support for assistance.

If the LK LED for a twisted pair port on an AT-CV5M01 card is OFF, perform the following:

ˆCheck that the end node connected to the port is powered ON and is operating properly.

ˆCheck that the twisted pair cable is securely connected to the twisted pair port on the switch and on the end node.

ˆMake sure that the twisted pair cable does not exceed 100 meters (328 feet) and that you are using a Category 5 or better cable.

Converteon™ Line Cards

LK LED is

Blinking

LK LED is OFF

If the LK LED for either the fiber optic port or the twisted pair port is blinking, refer to Appendix A in the Converteon™ Media Converter Line Cards Reference Guide.

If the LK LED for a twisted pair port is OFF, do the following:

ˆCheck that the end node connected to the port is powered ON and is operating properly.

ˆCheck that the twisted pair cable is securely connected to the twisted pair port on the switch and on the end node.

ˆMake sure that the twisted pair cable does not exceed 100 meters (328 feet) and that you are using a Category 5 or better cable.

ˆCheck for MissingLink™ option.

If the LK LED for a fiber optic port is OFF, do the following: