ˆVerify that the end node connected to the port is ON and is operating properly.

ˆCheck that the fiber optic cable is securely connected to the fiber optic port on the media converter and on the end node.

ˆCheck to be sure that the end node connected to the port is operating at the same port speed.

ˆVerify the fiber connections are correct that is the converter’s TX port is connected to the end node’s RX port, and the converter’s RX port is connected to the end node’s TX port.

ˆCheck to be sure that the end nodes connected to the switch are operating at the same duplex mode.

ˆTest the attenuation on the fiber cable to ensure that it does not exceed acceptable values.

ˆVerify that you are using the appropriate type of fiber optic cables and that you have not exceeded the maximum operating distances.

ˆCheck that the operating specifications of the fiber optic port on the end node are compatible with the operating specifications of the fiber optic port on the converter.

If you are still experiencing problems after testing and troubleshooting the installation, contact Allied Telesis Technical Support for assistance. Refer to “Contacting Allied Telesis” on page 16 or visit our web site at www.alliedtelesis.com for support information.