Configuring Communication
It is recommended that firmware KIT files only be transferred over a direct connection and only when the panel is connected to a power supply. If battery power or wireless connection fails during a firmware upgrade, the panel flash file system may become corrupted.
The
Configuring and Using USB with a Virtual Master
NetLinx Studio can be setup to run a Virtual Master where the PC acts as the Master by supplying its own IP Address for communication to the panel. The PC is first equipped with the USB driver, the panel is then configured for USB communication, and then Studio is configured to act as the Master.
For a personal computer to establish a connection to a Modero panel via USB, the target computer must have the appropriate AMX USB driver installed. This installation is bundled into the latest TPDesign4 software setup process or can be downloaded independently from the main Application Files page on www.amx.com.
Step 1: Setup the Panel and PC for USB Communication
1.If you do not currently have the latest version of TPDesign4, navigate to www.amx.com > Tech Center > Downloadable Files > Application Files > NetLinx Design Tools section of the website and locate the AMX USB Driver executable (AMX USBLAN Setup exe).
2.Download this executable file to a known location on your computer.
3.Launch the Setup.exe and follow the
Step 2: Confirm the Installation of the USB Driver on the PC
The first time each AMX touch panel is connected to the PC it is detected as a new hardware device and the USBLAN driver becomes associated with it (panel specific). Each time thereafter the panel is "recognized" as a unique USBLAN device and the association to the driver is done in the background. When the panel is detected for the first time some user intervention is required during the association between panel and driver.
1.After the installation of the USB driver has been completed, confirm the proper installation of the large
If the panel is already powered, continue with steps 3.
The panel MUST be powered and configured for USB communication before connecting the
2.Connect the terminal end of the 12
3.After the panel
(for 3 seconds) to continue with the setup process and proceed to the Setup page.
4.Select Protected Setup > System Settings (located on the
5.Toggle the blue Type field (from the Master Connection section) until the choice cycles to USB. Refer to the System Settings Page section on page 132 for more information about the fields on this page.
7" Modero Widescreen Touch Panels | 53 |
|
|