Upgrading Modero Firmware
Upgrading Modero Firmware
Before beginning the Upgrade process:
Setup and configure your NetLinx Master. Refer to the your particular NetLinx Master
Instruction Manual for detailed setup procedures.
Calibrate and prepare the communication pages on the Modero panel for use. Refer to the
Panel Calibration section on page 49.
The latest CV7 firmware kit file is now
Only CV7 firmware should be loaded onto ithis specific panel type.
This new firmware also provides both backwards compatibility with the previous 802.11b cards and new security protocols for the new 802.11g wireless CF card.
Refer to the NetLinx Studio version 2.x Help file for more information on uploading files via Ethernet.
Configure your panel for either direct connect or wireless communication. Refer to the
Configuring Communication section on page 51 for more information.
It is recommended that firmware Kit files only be transferred over a direct Ethernet connection and only when the panel is connected to a power supply.
If battery power or wireless connection fails during a firmware upgrade, the panel flash file system may become corrupted.
The process of updating firmware involves the use of a communicating NetLinx Master. The required steps for updating firmware to a Modero panel are virtually identical to those necessary for updating Kit files to a NetLinx Master (except the target device is a panel instead of a Master). Refer to either your Master’s literature or Studio 2.x Help file for those procedures.
A touch panel which is not using a valid username and password will not be able to communicate with a secured Master. If you are updating the firmware on or through a panel which is not using a username or password field, you must first remove the Master Security feature to establish an unsecured connection.
Upgrading the Modero Firmware via the USB port
Before beginning with this section, verify your panel is both powered and the
securely inserted into the PC’s USB port. The panel must be
Establishing a USB connection between the PC and the panel, prior to installing the latest NetLinx Studio and TPDesign4 applications will cause a failure in the USB driver installation.
This driver must first be saved to the PC as part of the new NetLinx Studio and TPDesign4 application installations.
Step 1: Configure the panel for a USB Connection Type
1.After the installation of the USB driver has been completed; confirm the proper installation of the large
2.After the CV7 panel
3.Select Protected Setup > System Settings (located on the
7" Modero Widescreen Touch Panels | 81 |
|
|