Upgrading Modero Firmware

6.Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx Master Settings dialog (FIG. 77).

7.From within this dialog enter the System number (default is 1).

8.Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio application.

9.Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System value is one.

10.Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.

The panel will not appear as a device below the virtual system number (in the Online Tree tab) until both the system number used in step 7 for the Virtual NetLinx Master (VNM) is entered into the Master Connection section of the System Settings page and the panel is restarted.

If the G4 panel does not appear, refer to the Troubleshooting section on page 185 for more information.

Step 3: Confirm and Upgrade the firmware via the USB port

Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication between the mini-USB Program port on the touch panel and the PC. This method of communication is used to transfer firmware Kit files and TPD4 touch panel files.

A mini-USB connection is only detected after it is installed onto an active panel. Connection to a previously powered panel which then reboots, allows the PC to detect the panel and assign an appropriate USB driver.

1.Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured properly using the steps outlined in the previous two sections.

2.With the panel already configured for USB communication and the Virtual Master setup within NetLinx Studio, its now time to verify the panel is ready to receive files.

3.After the Communication Verification dialog window verifies active communication between the Virtual Master and the panel, click the OnLine Tree tab in the Workspace window (FIG. 78) to view the devices on the Virtual System. The default System value is one.

4.Right-click on the System entry (FIG. 78) and select Refresh System to re-populate the list. Verify the panel appears in the OnLine Tree tab of the Workspace window.

The default Modero panel value is 10001.

Showing the Virtual Master firmware version and device number

Shows NetLinx Studio version number

Showing the current Modero panel firmware version and device number

FIG. 78 NetLinx Workspace window (showing the panel connection via a Virtual NetLinx Master)

7" Modero Widescreen Touch Panels

83

 

 

Page 93
Image 93
AMX CV7 manual Confirm and Upgrade the firmware via the USB port, Default Modero panel value is