Configuring Communication

3.Press the Mode field (to set the connection Mode) until the choice cycles to the word Listen. The System Number and Master IP/URL fields are then greyed-out.

4.Enter a username and password (into their respective fields) if the target Master has been previously secured.

5.Select the OnLine Tree tab from the Workspace window.

6.Select Diagnostics > URL Listing from the Main menu (FIG. 71).

System Address reflects the value set in the Device Addressing tab

Used to obtain an existing URL List from Master

Used to set the URL List on Master

FIG. 71 URL List dialog

7.Enter the System and Device number for the specific Master associated with your panel (as seen in the OnLine Tree tab).

8.Click Add and enter the IP Address of the Modero touch panel into the Add URL dialog.

9.Click OK to enter your IP Address and add it to the list.

10.Click Done once you are finished adding your panel information to the list.

11.Press the on-screen Reboot button to save any changes and restart the panel.

Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode

In this mode, enter the System Number of the NetLinx Master. This mode instructs the Modero to search for a Master that uses the same System Number (assigned within the Master Connection section) and

resides on the same Subnet as itself.

1.Toggle the blue Type field until Ethernet is selected (from the Master Connection section of the System Settings page).

2.Press the Mode field until the choice cycles to the word Auto.

3.Press the System Number field to launch a Keypad and enter the value for the system number of the NetLinx Master. This value can be obtained from the NetLinx Studio program > OnLine Tree of the Workspace window.

4.Do not alter the IP Settings section, of the System Settings page, as these fields are not applicable to this connection mode.

5.Enter a username and password (into their respective fields) if the target Master has been previously secured.

6.Press the on-screen Reboot button to both save any changes and restart the panel.

7.After the panel powers-up, press the grey Front Setup Access button for 3 seconds to open the Setup page and confirm there is an active connection.