Configuring Communication

8.Press the Web Control Name field to open the Web Name keyboard.

9.From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This information is used by the NetLinx Security Web Server to display on-screen links to the panel. The on-screen links use the IP Address of the panel and not the name for communication (FIG. 73).

FIG. 73 Sample relationship between G4 Web Control and Mange WebControl Connections window

10.Press Done after you are finished assigning the alpha-numeric string for the Web Control name.

11.Press the Web Control Password field to open the Web Password keyboard.

12.From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4 Authentication session password associated with VNC web access of this panel.

13.Press Done after you are finished assigning the alpha-numeric string for the Web Control password.

14.Press the Web Control Port field to open the Web Port Number keypad.

15.Within the keypad, enter a unique numeric value to be assigned to the port the VNC Web Server is running on. The default value is 5900.

16.Press Done when you are finished entering the value. The remaining fields within the G4 Web Control Settings section of this page are read-only and cannot be altered.

17.Press the Up/Down arrows on either sides of the G4 Web Control Timeout field to increase or decrease the amount of time the panel can remain idle (no cursor movements) before the session is closed and the user is disconnected.

18.Press the Back button to open the Protected Setup page.

19.Press the on-screen Reboot button to save any changes and restart the panel.

Verify your NetLinx Master’s IP Address and System Number have been properly entered into the Master Connection section of the System Settings page.

7" Modero Widescreen Touch Panels

77

 

 

Page 87
Image 87