Firmware Pages and Descriptions

The elements of the G4 Web Control page are described in the table below:

G4 Web Control Page Elements

Back:

Saves the changes and returns you to the previously active touch panel page.

 

 

Connection Status icon:

This visual display of the connection status allows the user to have a current

 

visual update of the panel’s connection status regardless of what page is

 

currently active.

 

• A Lock only appears on the icon if the panel has established a connection

 

with a currently secured target Master (requiring a username and password).

 

 

G4 Web Control Settings:

Sets the IP communication values for the touch panel and contains:

Enable/Enabled

 

• The Enable/Enabled button allows you to toggle between the two G4

 

activation settings:

 

- Enable - deactivates the G4 Web Control feature on the panel.

 

- Enabled - activates the G4 Web Control feature on the panel and allows

 

an external PC running a VNC client to access the panel (after the

 

remaining fields are configured).

Network Interface Select

 

Displays the detected method of communication to the web:

 

Wired is used when a direct Ethernet connection is being used for

 

communication to the web. This is a default setting if no wireless interface

 

card is detected by the panel.

 

Wireless is used when a wireless card is detected within the internal card

 

slot. This method provides an indirect communication to the web via a

 

pre-configured Wireless Access Point.

Web Control Name

 

Allows you to enter a unique alpha-numeric string that is used as the display

 

name of the panel within the Manage WebControl Connections window of the

 

new NetLinx Security browser window.

 

• This Web Control tab displays a G4 icon alongside the link to the Web Control

 

Name given to this panel (FIG. 96).

Web Control Password

 

Allows you to enter the G4 Authentication session password associated for

 

VNC web access of this panel.

Web Control Port

 

Allows you to enter the port value that the VNC Web Server runs on.

 

• Default value is 5900.

Maximum Number of

 

This read-only field displays the maximum number of users that can be

Connections

simultaneously connected to the target panel via the web.

 

• Default value is 1.

Current Connection Count

 

This read-only field displays the current number of users connected to the

 

target panel via the web. This value cannot exceed the Maximum number field.

 

 

G4 Web Control Timeout:

Sets the length of time (in minutes) the panel can remain idle (no cursor

 

movements) before the session is closed and the user is disconnected.

 

• Minimum value = 0 minutes (panel never times-out)

 

• Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)

 

 

Refer to the Using G4 Web Control® to Interact with a G4 Panel section on page 76 for more detailed instructions on how to use the G4 Web Control page with the new web-based NetLinx Security application.

104

7" Modero Widescreen Touch Panels

Page 114
Image 114
AMX CV7 G4 Web Control Page Elements, G4 Web Control Settings, Remaining fields are configured, G4 Web Control Timeout