Section 3 Initial Setup

purpose safety switch, choose Safety and enter a Description. If the line is unused, choose Unused. (Note: The “Control” option is not used by the current version of the LC controller.)

3. Repeat for all 8 input lines.

Output Line Settings

Anaheim Automation’s LC software can control up to 8 output lines to activate devices such as the spindle or coolant pump. You can manipulate any or all of the output lines with user defined M codes. Please see the LC Hardware Guide for more hardware details including the pin layout of the output line connector.

4To Configure the Output Lines

1.Choose Output Lines from the Setup menu. The Output Lines Setup dialog box will appear.

2.In the Description text boxes, type descriptions for each device connected to the output lines.

4To define an M-code to control output lines

1.In the M Code text box type the number for the M-code that you want to define.

2.In the Description text box type a phrase which best describes the action taken when this M-code is executed.

3.In the Output Line Action pull-down menus, choose the action for each line upon execution of the M-code. The choices are On, Off, or “–“, where the “-“ indicates that the state of the line remains unchanged.

Page 40