Section 7 Driver

Section 6. I/O CONNECTIONS

WIRING

BE VERY CAREFUL WHEN DOING ANY WIRING. IMPROPER WIRING WILL DAMAGE THE MOTOR SIGNAL GENERATOR.

The receptacle that plugs unto this connector is a Molex-Waldom Mini –Fit Jr. Series 16 pin receptacle (part number 39-01-2160), the female pins (part number 39-00-0039). The input lines as seen on the package as arranged as follows:

INPUT – The connector for up to 8 input lines. The most common use of the input is for limit or safety switches. These lines are all TTL level inputs. When a switch is open, its input signal is High (+5V). When a switch is closed, its input signal is Low (0V).

All switches can be wired normally open (NO) or normally closed (NC), Software Selectable. Each Normally Closed System must have all unused inputs wired to ground (0V). Each Normally Open System must have all unused inputs left Open. When any of the inputs line are open the Red Limit Light will illuminate and a signal will be sent to the host PC to indicate which input line(s) went high.

If you are not using the input lines, the limit light will always be illuminated.

If you experience unexpected limit errors, make sure that the Signal Generator Model 401A option is chosen in the System Options setup screen and all input lines are properly defined in the Input Lines Setup screen.

OUTPUT – The connector for up to 8 output lines. These lines are all optically isolated, TTL level outputs. Low is 0V and High is +5V.

Page 79
Image 79
Anaheim DPJ72LC2, DPJ72LC3, DPJ72LC4 manual O Connections