General Information

Opening the Unit

The iMac (27-inch, Mid 2010) has a glass panel that attaches to the front, which must be removed prior to replacing any module on the unit.

Important: The glass panel should only be removed by Apple-authorized technicians. Read and follow all of the cleaning and handling recommendations to prevent damaging the glass and LCD panel.

Follow ESD precautions when the front bezel and the LCD display are removed.

Required Tools

Special tools are required to remove, handle and clean the glass panel, such as the following.

ESD-safe workstation, including an ESD mat and wrist or heel strap

ESD bags (for storing ESD-sensitive parts while removed from unit)

Magnetized Torx T10 screwdriver

Magnetized Torx T8 screwdriver

Magnetized Torx T6 screwdriver

Phillips #2 screwdriver

Black stick (nylon probe, Apple part #922-5065) or other non-conductive nylon or plastic flat-blade tool

Kapton tape

Magnifying glass, for reading serial number etched on bottom of stand

Digital volt meter (for troubleshooting)

Soft, clean towel or cloth (to protect display and removed parts from scratches)

For more information about tools, refer to:

kBase #HT3452: Hand Tools for Desktop and Portable Repairs

In addition, the following software programs are required for troubleshooting:

Apple Service Diagnostic (ASD), version 3S140 or later

Apple Hardware Test (AHT), version 3A202 or later

Bluetooth Service Diagnostic (BSD)