Installing the Cache Coherency Filters

NOTE

If the profusion carrier tray is removed, we recommend that you install the cache coherency filters before installing the profusion carrier tray.

See Figure 43.

1.Observe the safety and ESD precautions at the beginning of this chapter.

2.Remove the Mezzanine Extraction Tool/Cache Coherency Hold Down from the front of the processor retention bracket by pulling out the plastic retaining pin.

3.With the keyed or notched edge of the filter oriented toward the back of the system, insert the filter into the connector.

4.Press down firmly on the filter until the front lock retaining latch moves to the locked position.

5.Push up on the retaining latch to ensure the filter is properly locked into position.

6.Replace the hold down bracket by aligning the tab and the plastic retaining pin on the front of the processor retention bracket. Once aligned, push in on the pin, locking the bracket in place.

SRPL8 Server System Product Guide

133

Page 133
Image 133
Intel SRPL8 manual Installing the Cache Coherency Filters