Removing a Power Supply

CAUTIONS

Turn off peripheral devices: If the chassis contains only two power supplies, turn off all peripheral devices connected to the server. Then turn off the server power with the push-button on/off switch on the front panel.

Populate all bays: Figure 19 shows the far-right power supply bay vacant. To ensure correct airflow, you must populate this bay with a redundant power supply or cover panel. The figure is intended to show a power supply bay with the supply removed and not yet replaced, not an acceptable configuration for a system during operation.

See Figure 19.

1.Look at the yellow FAIL LEDs on the power supplies to determine which one is defective.

2.Pull the power supply handle down to unlock it from the chassis.

3.Pull the power supply straight back, out of the chassis. Set it aside.

B

A

OM07324

Figure 19. Removing a Power Supply

A.Pull down handle first

B.Slide power supply out

SRPL8 Server System Product Guide

89

Page 89
Image 89
Intel SRPL8 manual Removing a Power Supply