POST Error Codes and Messages

The following error codes and messages are representative of various conditions BIOS identifies. The exact strings and error numbers may be different from those listed here.

Table 17. POST Error Codes and Messages

Code

0200

0210

0211

0213

0220

0230

0231

0232

0250

0251

0260

0270

0280

0281

0297

02B0

02B1

02B2

02B3

02D0

02F0

02F4

02F5

02F6

02F7

8108

8110

814B

8150

8152

8153

8160

Error message

Failure Fixed Disk

Stuck Key

Keyboard error

Keyboard locked - Unlock key switch

Monitor type does not match CMOS - Run SETUP

System RAM Failed at offset

Shadow RAM Failed at offset

Extended RAM Failed at offset

System battery is dead - Replace and run SETUP

System CMOS checksum bad - Default configuration used

System timer error

Real-time clock error

Previous boot incomplete - default configuration used

Memory size found by POST differed from EISA CMOS

Extended memory error

Diskette drive A error

Diskette drive B error

Incorrect Drive A type - run SETUP

Incorrect Drive B type - run SETUP

System cache error - Cache disabled

CPU ID

EISA CMOS not writeable

DMA Test Failed

Software NMI Failed

Fail-safe timer NMI failed

Watchdog Timer failed on last boot

Server Management Interface filed to function

BMC in Update Mode

NVRAM Cleared By Jumper

ESCD Data Cleared

Password Cleared By Jumper

Unable to apply BIOS Update for Board 2 Processor 1

continued

SRPL8 Server System Product Guide

167

Page 167
Image 167
Intel SRPL8 manual Post Error Codes and Messages, Error message