Front Side Bus (FSB) Termination Board Assembly

The profusion carrier provides connectors for two processor mezzanine boards. Each board provides four Slot 2 connectors for Pentium III Xeon processors packaged in S.E.C. cartridges. If any Slot 2 connector is depopulated, a termination board assembly must be installed in the connector to properly terminate the signals on the FSB.

For example, if only two slots in a mezzanine board are populated with processors, you need FSB termination board assemblies in the two unpopulated processor slots.

The assembly is a termination board packaged in plastic housing.

Removing a Termination Board

See Figure 53.

1.Observe the safety precautions, warnings, and cautions at the beginning of this chapter.

2.Remove the top cover (see “ Removing the Top Cover” on page 98).

3.Remove the processor holddown bracket and set it aside.

4.Simultaneously rotate the eject/insert levers of the terminator module outward to eject the module out of the Slot 2 connector.

5.Slide the module out of the processor retention bracket slot guides, and place it component- side down on a nonconductive, static-free surface.

150

Upgrading Boardset Components

Page 150
Image 150
Intel SRPL8 manual Front Side Bus FSB Termination Board Assembly, Removing a Termination Board