System Management Submenu

Default values are in bold typeface.

Feature

Option

Firmware SMIs

Disabled

 

Enabled

 

 

System Event Logging

Disabled

 

Enabled

Clear Event Log

Disabled

 

Enabled

 

 

Memory Scrubbing

Disabled

 

Enabled

AERR Enable

Disabled

 

Enabled

 

 

Assert NMI on BERR

Disabled

 

Enabled

 

 

Assert NMI on PERR

Disabled

 

Enabled

 

 

Assert NMI on SERR

Disabled

 

Enabled

Enable Host Bus Error

Disabled

 

Enabled

FPC Error Check

Disabled

 

Enabled

 

 

HSC Error Check

Disabled

 

Enabled

 

 

Server Management Information

 

Description

Enables SMI generation by agents on the Intelligent Platform Management Bus (IPMB). Because BIOS requires SMIs for various tasks, setting this field to disabled does not disable all sources of SMIs.

Enabled: logs critical system events.

Clears the System Event Log (SEL). This option is reset to Disabled on each boot.

Enables memory scrubbing by the Profusion chip set.

Enables AERR to be asserted on the processor host buses.

Enables BERR to be reported as a critical event via NMI. Requires SERR to be enabled as well.

Enables PERR to be reported as a critical event via NMI. Requires SERR to be enabled as well.

Enables SERR to be reported as a critical event via NMI.

Enables ECC checking on the processor buses.

Enables Front Panel Controller (FPC) checking. If enabled, BIOS verifies that it can communicate with the FPC.

Enables Hot-swap Controller (HSC) checking. If enabled, BIOS verifies that it can communicate with the HSC.

Selects Server Management Information submenu.

SRPL8 Server System Product Guide

47

Page 47
Image 47
Intel SRPL8 manual System Management Submenu, Feature Option