SETUP COMMANDS – ADVANCED

Advanced Speaker

Command Parameters Description Parameter values
BAS BASsy Bass Levels y may have a value in the range -6 to +6:
-6 = –6dB
+6 = +6dB
TRB TRBsy Treble Levels y may have a value in the range -6 to +6:
-6 = –6dB
+6 = +6dB
STB STBx Auto Stereo Tone Bypass

Advanced Video

Command Parameters Description Parameter values
OSD zOSDx OSD
VIA VIAi Video Input AUX
VIC VICi Video Input CD
VIT VITi Video Input Tape
VIM VIMi Video Input Multichannel
ANV ANVy Audio and Video y may have the values 0 to 1, as follows:
0 = Tracked, 1 = Separate.
HQS HQSyi HQ Video Setting y may have the values 0 to 2, as follows:
0 = HQ Vid 1, 1 = HQ Vid, 2 = HQ Vid 3.

Advanced Digital

Command Parameters Description Parameter values
DIG DIGyi Digital Inputs y may have the values 0 to 6; i=1 (for digital input) or i=2 (for source assigned).

Advanced zone 2

Command Parameters Description Parameter values
FVL FVLx Zone 2 Fix Volume
SBY zSBYy Standby y may have the values 0 to 1, as follows:
0 =Local Only, 1 = All Off.
CZI CZIx Zone 1 Control
ACC ACCix Zone 2 Access 0 =None, 1 = All.

Advanced Analogue

Command Parameters Description Parameter values
ANS ANSiy Analogue Settings y may have the values 0 to 3, as follows:
0 = Low 0.5V, 1 = Medium 1V, 2 = Reference 2V, 3 = High 4V.

Save Settings

Command Parameters Description Parameter values
SAV SAVy Save Preset y may have the values 0 to 5, as follows:
0 = Current Preset, 1 = Preset 1, 2 = Preset 2, 3 = Preset 3, 4 = Preset 4, 5 =
Preset 5.
PNM PNMyn Preset Name y may have the values 0 to 5, as follows:
0 = Current Preset, 1 = Preset 1, 2 = Preset 2, 3 = Preset 3, 4 = Preset 4, 5 =
Preset 5, n = up to 14 characters.