CHAPTER 6 TROUBLESHOOTING

I-4

All black

User Check

(1)Clean the corona wire of the drum unit.

(2)The drum unit may be damaged. Install a new drum unit.

Possible cause

Step

Check

Result

Remedy

Ground

contacts

 

 

 

 

 

 

 

 

 

 

 

Corona failure

1

Is the corona wire dirty?

Yes

Clean the corona wire

 

 

 

 

with the wire cleaner.

 

 

 

 

 

 

 

 

 

 

 

 

2

Is the corona wire broken?

Yes

Replace the drum

 

 

 

 

 

unit.

 

 

 

 

 

 

 

 

3

Are the charge electrodes

Yes

Clean both electrodes.

 

 

between the printer body and

 

 

 

 

the drum unit dirty?

 

 

 

 

 

 

 

 

 

Harness

4

Is the laser unit connected to

No

Connect the harness

 

connection

 

the main PCB correctly?

 

between the laser unit

 

 

 

 

 

and the main PCB

 

 

 

 

 

correctly.

 

 

 

 

 

 

 

High-voltage

5

Is the problem solved after

Yes

Replace the high-

 

power supply

 

replacing the high-voltage

 

voltage power supply

 

PCB failure

 

power supply PCB?

 

PCB.

 

 

 

 

 

 

 

Main PCB failure

6

Is the problem solved after

Yes

Replace the main

 

 

 

replacing the main PCB?

 

PCB.

 

 

 

 

 

 

 