CHAPTER 3 THEORY OF OPERATION

1.4Engine PCB

The gate array which transforms the serial signal from the main PCB into the parallel signal is mounted on the engine PCB.

The engine PCB controls the following parts by using the transferred signal data;

Main motor

Toner sensor

Panel PCB

Cover sensor

Fan motor

Front registration sensor

Thermistor

Rear registration sensor

Polygon motor

Upper paper cassette sensor (HL-1250/1270N only)

Solenoid

Lower paper cassette registration sensor (HL-1250/1270N only)

High-voltage power supply

For the circuit diagram of the engine PCB, see Appendix 18.

1.5BR-net PCB (for HL-1270N only)

The BR-net PCB is connected to the ASIC mounted on the main PCB through the PCI bus.

The Ethernet controller, AM79C973AKC is mounted on the BR-net PCB. The controller incorporates the 10/100 Mbps physical interface which conforms to IEEE 802.3 and is connected with the external Ethernet through the RJ-45 connector.

For the circuit diagram of the BR-net PCB, see Appendix 19.

3-18

Page 60
Image 60
Brother HL-1030, 1240, 1250 service manual Engine PCB, BR-net PCB for HL-1270N only