CHAPTER 2 INSTALLATION AND BASIC OPERATION

6.1.3Print configuration page

Press the Network Test button for less than 5 seconds to print a configuration page.

TEST button

Fig. 2-32

6.2Functions

6.2.1LED functions

L-LED F-LED A-LED

(green) (orange) (green)

Fig. 2-33

L-LED (green): Link activity

This LED is on if there is a valid connection to the network (either 10BaseT or 100BaseTX). It is off if no network is detected.

F-LED (orange): Fast Ethernet

This LED will be on if the print server is connected to a 100BaseTX Fast Ethernet network. It is off if the print server is connected to a 10BaseT network.

A-LED (green): Transmission activity

This LED will blink as the print server receives or transmits data.

6.2.2Factory default setting

If you wish to reset the print server back to its default factory settings (resetting all information such as the password and IP address information), hold down the Network Test button for more than 5 seconds.