CHAPTER 6 TROUBLESHOOTING

I-16

Black spots

User Check

(1)If the problem is not solved after printing a few pages, the drum unit may have glue from label stock on the photosensitive drum surface. Refer to Step 1 in the table below and NOTE in the previous page.

(2)The drum unit may be damaged. Install a new drum unit.

Possible cause

Step

Check

Result

 

Remedy

 

 

 

 

 

 

Drum unit

1

Are the spots at 94mm

Yes

1)

If toner or glue remains

 

 

intervals?

 

 

stuck, wipe it off gently with a

 

 

(The problem is not solved

 

 

cotton swab. (Refer to NOTE

 

 

after printing a few pages.)

 

 

in the previous page.)

 

 

 

 

2)

If the photosensitive drum is

 

 

 

 

 

scratched or deteriorated

 

 

 

 

 

(exposed), replace the drum

 

 

 

 

 

unit.

 

 

 

 

 

 

Fixing unit

2

Are the spots at 79mm

Yes

1)

Check and clean the heat

 

 

intervals?

 

 

roller with a cloth dampened

 

 

(The problem is not solved

 

 

with alcohol.

 

 

after printing a few pages.)

 

2)

Replace the fixing unit.

 

 

 

 

 

High-voltage

3

Is the problem solved after

Yes

Replace the high-voltage power

power supply

 

replacing the high-voltage

 

supply PCB.

PCB failure

 

power supply PCB?

 

 

 

 

 

 

 

 

 

I-17

Black band

Possible cause

Step

Check

Result

 

Remedy

Ground

 

 

 

 

 

 

contacts

 

 

 

 

 

 

Corona failure

1

Is the wire cleaner at its home

No

Return the wire

 

 

 

position?

 

cleaner to its home

 

 

 

 

position.

 

 

 

 

 

 

 

 

Corona failure

2

Is the corona wire dirty?

Yes

1)

Clean the corona

 

 

 

 

 

wire.

 

 

 

 

2)

If the problem still

 

 

 

 

 

 

appears after

 

 

 

 

 

 

cleaning, replace

 

 

 

 

 

 

the drum unit.

 

 

 

 

 

 

 

 

6-36

Page 158
Image 158
Brother 1250, HL-1030, 1240 service manual Black spots, Black band