Parallel Submenu

Parallel Submenu

Parallel Submenu

Centronics Interface

IMPORTANT The Centronics parameters in the printer must be set the same as the Centronics interface in the host computer. Otherwise, the printer might not work online, and data characters from the computer might not print or might print as “garbled” text.

* = Factory Default

Parallel

(from page 103)

Centronics

Data Bit 8

Data Polarity Strobe Polarity

Resp. Polarity

Busy On Strobe

Latch Data On

Enable*

Standard*

Standard*

Standard*

Disable

Inverted

Inverted

Inverted

Enable* Disable

Leading* Trailing

Prime Signal

Enable*

Disable

TOF Action

Reset*

Do Nothing

Buffer Size in

K

8* (1-16)

The Centronics submenu provides the options and settings available to configure the interface as required for your application. These options and available settings are outlined in the following paragraphs.

Data Bit 8

Enable. Allows access to the extended ASCII character set.

Disable. The printer interprets bit 8 of each incoming data character as a zero, regardless of its actual setting.

Data Polarity

The Data Polarity parameter must be set to match the data polarity of your host computer.

Standard. Does not expect the host computer to invert the data.

Inverted. Expects the data received on the data lines from the host computer to be inverted. Ones become zeros, and vice-versa.