Removal and Installation

Removal and Installation

The shipping kit for this printer includes 220 ohm pull-up and 330 ohm pull- down alternate terminating resistors. If you install the 220 ohm pull-up resistor, you must also install the 330 ohm pull-down resistor. Table 13 lists the three terminating resistor configurations you can install:

Table 13. Terminating Resistor Configurations

Configuration

Pull-Up (RP1)

Pull-Down (RP2)

 

 

 

 

 

 

Factory Default

470 ohm

1K ohm

 

 

 

Alternate 1

220 ohm

330 ohm

 

 

 

Alternate 2

1K ohm

none

 

 

 

Removal and Installation

IMPORTANT This is an involved maintenance procedure; only a trained technician should perform this procedure.

The procedure for removing and installing terminating resistors is provided in the Maintenance Manual.