Flow Control: None

Redirection After BIOS POST: Always

Terminal Type: ANSI

See "Remote Access Configuration" on page 86 for details. Make sure the last four options syncs with the host and client.

7In the Server screen, select BMC LAN Configuration and press <Enter>.

8In the BMC LAN Configuration screen, verify the following settings:

BMC LAN Port Configuration: Dedicated-NIC

BMC NIC IP Source: DHCP or Static (Use DHCP if your network servers are using automatic assignment of IP addresses)

IP Address: 192.168.001.003

Subnet Mask: 255.255.255.000

Gateway Address: 000.000.000.000

See "Set BMC LAN Configuration" on page 84 for details. Make sure the host and client are on the same network

9Press <Esc> to return to the System Setup screen. Press <Esc> again, and a message prompts you to save the changes.

To activate console redirection via a shared BMC management port, you must configure the following settings:

1Connect the sled system board and node power distribution board with a BMC cable.

2Connect the network cable to the Ethernet connector 1. See Figure 1-1 for the location of the Ethernet connector 1 on the sled.

3Press <F2> immediately after a power-on or reboot to enter System Setup.

4In the System Setup screen, select the Server menu and press <Enter>.

5In the Server screen, select Remote Access Configuration and press <Enter>.

6In the Remote Access Configuration screen, verify the following settings:

Remote Access: Enabled

Serial port number: COM2

50

Using the System Setup Program

Page 50
Image 50
Dell C8220 owner manual Using the System Setup Program