SB Error

Message: “Critical Interrupt Sensor, Correctable, MCU Parity Error”

Table 1-6. SB Error

Byte

Field

Value

Description

 

 

 

 

1

NetFunLun

10h

 

2

Platform Event Command

02h

 

3

Generator ID

01h

Generated by BIOS

4

Event Message Format

04h

Event Message Format Revision.

 

Version

 

04h for this specification

5

Sensor Type

13h

Critical Interrupt

6

Sensor Number

77h

SB Sensor ID (depend on

 

 

 

platform)

7

Event Direction Event Type

6Fh

Bit 7: 0 = Assert Event

 

 

 

Bit 6: 0 = Event Type Code

8

Event Data1

AXh

07h: Correctable

 

 

 

08h: Uncorrectable

9

Event Data2

XXh

Bit 7:5Reserved Local error bit

 

 

 

number (4 ~ 0)

 

 

 

00000b: HT Periodic CRC Error

 

 

 

00001b: HT Protocol Error

 

 

 

00010b: HT Flow-Control Buffer

 

 

 

Overflow

 

 

 

00011b: HT Response Error

 

 

 

00100b: HT Per-Packet CRC Error

 

 

 

00101b: HT Retry Counter Error

 

 

 

00111b: MCU Parity Error

10

Event Data3

FFh

FFh: Not Present

 

 

 

 

32

About Your System

Page 32
Image 32
Dell C8220 owner manual SB Error Byte Field Value Description