Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

I1911

LCD Log Full.

LCD overflow message. A

Check the SEL for details

 

Check SEL to

maximum of ten error

on the events.

 

review all

messages can display

Remove AC power to the

 

Errors.

sequentially on the LCD.

 

system for 10 seconds or

 

 

The eleventh message

clear the SEL.

 

 

instructs the user to check

 

 

 

 

 

the SEL for details on the

 

 

 

events.

 

I1912 SEL full.

The SEL is full of events

Review & clear

and is unable to log any

log.

more.

Check the SEL for details on the events, then clear the SEL.

I1920 iDRAC6 Upgrade

iDRAC6 Express card has Information only

Successful

been installed correctly

W1228 RAID

Warns predictively that

Controller

the RAID battery has less

battery

than 24 hours of charge

capacity <

left.

24hr.

 

Allow RAID battery to charge to greater than 24 hours of sustained charge.

If problem persists, replace RAID battery. See "Installing a RAID Battery" on page 128.

W1627 Power required The system configuration

>PSU wattage. requires more power than Check PSU and what the power supply can

config. provide.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.

W1628 Performance

The system configuration

degraded.

requires more power than

Check PSU and

what the power supply can

system

provide, but it can boot if

configuration.

throttled.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.