Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1810

Hard drive ##

The specified hard drive

See "Troubleshooting a

 

fault. Review

has experienced a fault.

Hard Drive" on page 174.

 

& clear SEL.

 

 

 

 

 

 

E1812

Hard drive ##

The specified hard drive

Information only.

 

removed. Check

has been removed from

 

 

drive.

the system.

 

E1920 iDRAC6 Upgrade

The iDRAC6 Express card

Failed

is not installed properly or

 

the card is bad.

If the problem persists, see "Getting Help" on page 193.

E1A14

SAS cable A

SAS cable A is missing or

Reseat the cable. If the

 

failure. Check

bad.

problem persists, replace

 

connection.

 

cable.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 193.

 

 

 

 

E1A15

SAS cable B

SAS cable B is missing or

Reseat the cable. If the

 

failure. Check

bad.

problem persists, replace

 

connection.

 

cable.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 193.

 

 

 

 

E1A1D

Control panel

USB cable to the control

Reseat the cable. If the

 

USB cable not

panel is missing or bad.

problem persists, replace

 

detected.

 

cable.

 

Check cable.

 

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 193.

 

 

 

 

E2010

Memory not

No memory was detected

Install or reseat memory

 

detected.

in the system.

modules. See "Installing

 

Inspect DIMMs.

 

Memory Modules" on

 

 

 

page 104 or

 

 

 

"Troubleshooting System

 

 

 

Memory" on page 167.

32

About Your System

Page 32
Image 32
Dell T710 E1810 Hard drive ##, Fault. Review, Clear SEL E1812 Hard drive ##, Removed. Check, Drive, E1920 iDRAC6 Upgrade