Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1410

Internal Error

Specified processor has an

Remove AC power to the

 

detected.

internal error. The error

system for 10 seconds and

 

Check "FRU X". may or may not have been

restart the system.

 

 

caused by the processor.

If the problem persists,

 

 

 

 

 

 

see "Getting Help" on

 

 

 

page 193.

 

 

 

 

E1414

CPU # temp

Specified processor is out

Ensure that the processor

 

exceeding

of acceptable temperature

heat sinks are properly

 

range. Check

range.

installed. See

 

CPU heatsink.

 

"Troubleshooting the

 

 

 

Processors" on page 179

 

 

 

and "Troubleshooting

 

 

 

System Cooling

 

 

 

Problems" on page 166.

 

 

 

 

E1418

CPU # not

Specified processor is

Ensure that the specified

 

detected.

missing or bad, and the

microprocessor is

 

Check CPU is

system is in an

properly installed. See

 

seated

unsupported

"Troubleshooting the

 

properly.

configuration.

Processors" on page 179.

 

 

 

 

E141C

Unsupported

Processors are in an

Ensure that your

 

CPU

unsupported

processors match and

 

configuration. configuration.

conform to the type

 

Check CPU or

 

described in the processor

 

BIOS revision.

 

technical specifications

 

 

 

outlined in your system’s

 

 

 

Getting Started Guide.

E141F CPU # protocol

The system BIOS has

error. Power

reported a processor

cycle AC.

protocol error.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 193.