Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Alert! Power

The system configuration of

If any system components

required exceeds

processor(s), memory

were just upgraded, return

PSU wattage.

modules, and expansion

the system to the previous

Check PSU and

cards may not be supported

configuration. If the system

system

by the power supplies.

boots without this warning,

configuration.

 

then the replaced

Alert!

 

component(s) are not

 

supported with this power

Continuing

 

 

supply. If Energy Smart

system boot

 

 

power supplies are installed,

accepts the risk

 

 

replace them with High

that system may

 

 

Output power supplies to

power down

 

 

use the components. See

without warning.

 

 

"Internal SD Module" on

 

 

 

 

page 119.

Alert! Redundant

Memory Sparing or Memory

memory disabled!

Mirroring was enabled in the

Memory

system setup program, but

configuration

the current configuration

does not support

does not support redundant

redundant

memory. A memory module

memory.

may be faulty.

Check the memory modules for failure. See "Troubleshooting System Memory" on page 167. Reset the memory setting, if appropriate. See "Using the System Setup Program and UEFI Boot Manager" on page 57.

Alert! System

An error caused the system to

Check other system

fatal error

reboot.

messages for additional

during previous

 

information for possible

boot.

 

causes.

About Your System

41

Page 41
Image 41
Dell T710 Alert! Power, Required exceeds, PSU wattage, System boot, Alert! Redundant, Memory disabled, Alert! System, Boot