Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Plug & Play

Error encountered in

Install the NVRAM_CLR

Configuration

initializing PCIe device;

jumper in the clear position

Error

faulty system board.

(pins 1 and 3) and reboot the

 

 

system. See Figure 6-1 for

 

 

jumper location. If the

 

 

problem persists, see

 

 

"Troubleshooting the

 

 

Processors" on page 179.

 

 

 

Quad rank DIMM

Invalid memory

Ensure that the memory

detected after

configuration.

modules are installed in a

single rank or

 

valid configuration. See

dual rank DIMM in

 

"General Memory Module

socket.

 

Installation Guidelines" on

 

 

page 98.

Read fault

Requested sector not found

The operating system cannot read from the hard drive, optical drive, or USB device, the system could not find a particular sector on the disk, or the requested sector is defective.

Replace the optical medium, USB medium, or USB device. Ensure that the USB cables, SAS/SATA backplane cables, or optical drive cables are properly connected. See "Troubleshooting a USB Device" on page 160, "Troubleshooting an Optical Drive" on page 171, or "Troubleshooting a Hard Drive" on page 174 for the appropriate drive(s) installed in your system.

SATA Port x

There is no device connected Information only.

device not found

to the specified SATA port.