Table 1-2. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Unable to launch

System halted after F10

Restart the system and

System Services

keystroke because System

update the Unified Server

image. System

Services image is either

Configurator repository to

halted!

corrupted in the system

the latest software to restore

 

firmware or has been lost due

full functionality. See the

 

to system board replacement.

Unified Server

 

The iDRAC6 Enterprise card

Configuration user

 

flash memory may be

documentation for more

 

information.

 

corrupted.

 

 

 

 

Restore the flash memory

 

 

using the latest version on

 

 

support.dell.com. See the

 

 

iDRAC6 user's guide for

 

 

instructions on performing a

 

 

field replacement of the

 

 

flash memory.

 

 

 

Unexpected

Improperly seated memory

Reseat the memory modules.

interrupt in

modules or faulty

See "Troubleshooting

protected mode

keyboard/mouse controller

System Memory" on

 

chip.

page 167. If the problem

 

 

persists, see "Getting Help"

 

 

on page 193.

 

 

 

Unsupported CPU

Processor(s) is not supported

Install a supported processor

combination

by the system.

or processor combination.

Unsupported CPU

 

See "System Battery" on

 

page 144.

stepping

 

 

 

detected

 

 

 

 

 

Unsupported DIMM

Invalid memory

Ensure that the memory

detected. The

configuration. The system

modules are installed in a

following DIMM

will run but with the

valid configuration. See

has been

specified memory module

"General Memory Module

disabled: x

disabled.

Installation Guidelines" on

 

 

page 98.