Table 1-1. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1620

Power Supply #

Specified power supply's

Check the AC power

 

(### W) AC

AC input is outside of the

source for the specified

 

power error.

allowable range.

power supply. If the

 

Check PSU

 

problem persists, see

 

cables.

 

"Troubleshooting Power

 

 

 

Supplies" on page 165.

 

 

 

 

E1624

Lost power

The power supply

See "Troubleshooting

 

supply

subsystem is no longer

Power Supplies" on

 

redundancy.

redundant. If the

page 165.

 

Check PSU

remaining power supply

 

 

cables.

fails, the system will shut

 

 

 

down.

 

E1626 Power Supply

The power supplies in the

Mismatch. PSU1

system are not the same

= ### W, PSU2

wattage.

= ### W.

 

Ensure that power supplies with matching wattage are installed. See the Technical Specifications outlined in your system’s Getting Started Guide.

E1629 Power required The system configuration

>PSU wattage. requires more power than Check PSU and the power supplies can

config.

provide, even with

 

throttling.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.

E1710 I/O channel

The system BIOS has

check error.

reported an I/O channel

Review & clear

check.

SEL.

 

Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system.