The DIVA Terminal Adapters Program for Windows 95/98/NT

Number Assignment (models without phone ports)

If your DIVA T/A is equipped with phone ports, see “Number Assignment (models with phone ports)” on page 44.

Within the Number Assignment group box, you can assign a previously configured number or numbers to your data ports for all your data connections. If you select a specific number for your data connections, you can then monitor the charges for your data calls. It is also helpful if your ISDN Service Provider offers a discount on all calls made to a favorite number.

Parameter

Description

Select a previously

This option allows you to select from the numbers you previously configured.

configured

You can select either one number or both numbers and assign them to your

number

data ports. For example, if you select the first number that you configured, all

 

data calls will use that number.

 

 

Protocol Options (models with phone ports)

Parameter

Description

Dynamic

This option is visible only if your DIVA T/A is equipped with phone ports and if

Bandwidth

the protocol is set to ‘MultiLink PPP‘, ‘MultiLink PPP with BACP‘, or ‘MultiLink

Allocation (DBA)

with AODI‘.

 

Dynamic Bandwidth Allocation (DBA) activates the DIVA T/A’s Phone Line

 

control for Multilink PPP connections. When activated, this function enables you

 

to initiate or receive telephone calls on your regular (non-ISDN) telephone

 

without interrupting your Multilink PPP connection.

 

The DBA function releases one B-channel, as required for phone calls, without

 

interrupting the data link. When the call is over, DBA automatically

 

re-establishes the Multilink PPP session by reconnecting the second B-channel,

 

if the throughput requires it.

 

 

DIVA T/A ISDN Modem User’s Guide Page 45