DIVA T/A ISDN Modem User’s Guide Page 47
The DIVA Terminal Adapters Program for Windows95/98/NT
For example, if your ISDN provider charges a particular amount for the first five minutes online, select 300 seconds in the Initial Billing Interval field. If your ISDN provider charges another amount for each subsequent minute online, select 60 seconds in the Billing Interval field.1st B-ChannelThe ‘1st B-Channel’ tab is only visible if the data protocol is set to ‘MultiLink PPP with AODI’.2nd B-Channel
If you have BACP configured, you can configure these options to specify when the 2nd B-channel will
be added to the connection as the traffic volume warrants.
Parameter Description
Delay before
opening
Specifies the amount of time (in seconds) the throughput on your D-channel must
exceed the Opening Threshold before the 1st B-channel is added to the AO/DI
connection.
For example, if you specify 5 seconds, and the Opening Threshold is 70%, once the
throughput on the D-channel reaches 70%, there will be a delay of 5 seconds before
the 1st B-channel is added to the AO/DI connection. If the throughput drops below
70% during the 5 seconds, the 1st B-channel will not be added to the connection.
Opening
Threshold
Specifies the threshold (percentage) that the throughput on your D-channel must
exceed before the 1st B-channel is added to the AO/DI connection.
Closing
Threshold
Specifies the threshold (percentage) that the throughput on your D-channel must be
below before the 1st B-channel is dropped from the AO/DI connection.
Parameter Description
Delay before
opening
Specifies the amount of time (in seconds) the throughput on your 1st B-channel
must exceed the Opening Threshold before the 2nd B-channel is added to the AO/DI
connection.
For example, if you specify 5 seconds, and the Opening Threshold is 70%, once the
throughput on the 1st B-channel reaches 70%, there will be a delay of 5 seconds
before the 2nd B-channel is added to the AO/DI connection. If the throughput drops
below 70% during the 5 seconds, the 2nd B-channel will not be added to the
connection.
Opening
Threshold
Specify the threshold (percentage) that the throughput on your 1st B-channel must
exceed before the 2nd B-channel is added to the AO/DI connection.
Closing
Threshold
Specify the threshold (percentage) that the throughput on your 2nd B-channel
connection must be below before the 2nd B-channel is dropped from the AO/DI
connection.