Galil DMC-1800 Configuring Hardware Banks, Figure A.4 – CB-50-80and CB-50-100Bracket Layout

Models: DMC-1800 DMC-1700

1 253
Download 253 pages 18.39 Kb
Page 234
Image 234
Figure A.4 – CB-50-80 and CB-50-100 Bracket Layout

WARNING! Make sure that you do not connect the 100 pin cable from the IOM-1964 Rev. A to the J1 motion I/O connector of the controller. Note the Error LED on the controller bracket to identify the motion I/O connector.

CB-50-80

End bracket

80 pin high density connector used for extended I/O

Error LED

DMC-17x8

End bracket

100 pin high density connector J1 used for motion I/O

Figure A.4 – CB-50-80 and CB-50-100 Bracket Layout

Configuring Hardware Banks

The extended I/O on the DMC-17x8 and DB-14064 is configured using the CO command. The banks of buffers on the IOM-1964 are configured to match by inserting the appropriate IC’s and resistor packs. The layout of each of the I/O banks is identical.

For example, here is the layout of bank 0: