Troubleshooting

Regarding the indicator lamps (continued)

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

 

 

 

 

 

 

 

There is a possibility that the interior portion

 

 

 

has become heated.

 

 

 

Please turn the power off, and allow the projector to

 

 

 

cool down at least 20 minutes. After the projector has

Blinking

 

 

sufciently cooled down, please make conrmation of

 

 

the following items, and then turn the power on again.

In Red

Turned

Lighting

• Is there blockage of the air passage aperture?

or

off

In Red

• Is the air lter dirty?

Lighting

 

 

• Does the peripheral temperature exceed 35°C?

In Red

 

 

 

 

• If the projector is used at an altitude of about 1600 m

 

 

 

 

 

 

(5250 feet) or higher, set ALTITUDE of the SERVICE

 

 

 

item in the OPTION menu to HIGH ( 57). If the

 

 

 

projector is used with a wrong setting, it may cause

 

 

 

damage to the projector itself or the parts inside.

 

 

 

It is time to clean the air filter.

Lighting

Simultaneous

Please immediately turn the power off, and clean or

change the air lter referring to the section Cleaning

In Green

blinking in Red

and replacing the air filter. After cleaning or changing

 

 

 

the air lter, please be sure to reset the lter timer.

 

 

 

After the remedy, reset the power to ON.

 

 

 

There is a possibility that the interior portion

Lighting

Alternative

has become overcooled.

Please use the unit within the usage temperature

In Green

blinking in Red

parameters (5°C to 35°C).

 

 

 

 

 

 

After the treatment, reset the power to ON.

Blinking In

 

 

At least 1 Power ON schedule is saved to the

Green for

Turned

Turned

projector.

approx. 3

off

off

Please refer to 3.1.7 Schedule Settings in the

seconds.

 

 

Network Guide.

NOTE • When the interior portion has become overheated, for safety purposes, the projector is automatically shut down, and the indicator lamps may also be turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. After the projector has sufciently cooled down, please make conrmation of the attachment state of the lamp and lamp cover, and then turn the power on again. If the projector is used at an altitude of about 1600 m (5250 feet) or higher, set ALTITUDE of the SERVICE item in the OPTION menu to HIGH (57). Otherwise, set it to NORMAL.

101

Page 110
Image 110
Hitachi CP-X3021WN Regarding the indicator lamps, There is a possibility that the interior portion, Has become heated