Hitachi CP-X2521WN, CP-X3021WN user manual

Models: CP-X2521WN CP-X3021WN

1 242
Download 242 pages 19.51 Kb
Page 217
Image 217
URL: http://pjlink.jbmia.or.jp/

 

 

PJLink command (continued)

 

 

 

Commands

Control Description

Parameter or Response

 

 

 

 

 

1st byte: Refers to Fan error; one of 0 to 2

 

 

2nd byte: Refers to Lamp error; one of 0 to 2

 

 

3rd byte: Refers to Temptrature error; one of 0 to

 

 

2

 

 

4th byte: Refers to Cover error; one of 0 to 2

ERST ?

Error Status inquiry

5th byte: Refers to Filter error; one of 0 to 2

 

 

6th byte: Refers to Other error; one of 0 to 2

 

 

 

 

 

The mearning of 0 to 2 is as given below

 

 

0 = Error is not detected; 1 = Warning; 2 =

 

 

Error

LAMP ?

Lamp Status inquiry

1st number (digits 1 to 5): Lamp Time

2nd number : 0 = Lamp off, 1 = Lamp on

 

 

INST ?

Input Source List inquiry

11 12 22 23 31 41 51 52

NAME ?

Projector Name inquiry

Responds with the name set in "PROJECTOR

NAME" of "NETWORK"

 

 

INF1 ?

Manufucturer's Name

HITACHI

inquiry

 

 

INF2 ?

Model Name inquiry

Your model name, "CP-X2021WN",

"CP-X2521WN" or "CP-X3021WN".

 

 

INFO ?

Other Information inquiry

Responds with the factory information and so

on

CLSS ?

Class Information inquiry

1

NOTE • The password used in PJLinkTM is the same as the password set in the Web Brouwser Comtrol. To use PJLinkTM without authentication, do not set any password in Web Browser Control.

For specications of PJLinkTM, see the web site of the Japan Business Machine and Information System Industries Association.

URL: http://pjlink.jbmia.or.jp/

31

Page 217
Image 217
Hitachi CP-X2521WN, CP-X3021WN user manual