Command Control via the Network (continued)

Command control settings

[TCP #23]

1. Command format

Same as RS-232C communication, refer to RS-232C Communicaton command format.

2. Response code / Error code ("h" shows hexadecimal)

Four of the response / error code used for TCP#23 are the same as RS-232C Communication (1)~(4). One authentication error reply (5) is added.

(1) ACK reply : 06h

Refer to RS-232C communication (10).

(2)NAK reply : 15h

Refer to RS-232C communication (10).

(3)Error reply : 1Ch + 0000h

Refer to RS-232C communication (10).

(4)Data reply : 1Dh + xxxxh

Refer to RS-232C communication (10).

(5)Authentication error reply : 1Fh + 0400h

When authentication error occurred, the projector returns the error code.

[TCP #9715]

1. Command format

The commands some datum are added to the head and the end of the ones of TCP#9715 are used.

Header

Data length

RS-232C command

Check sum

Connection ID

0×02

0×0D

13 bytes

1 byte

1 byte

[Header]

02, Fixed

[Data Length]

RS-232C commands byte length (0×0D, Fixed)

[RS-232C commands]

Refer to RS-232C Communication command format (9).

[Check Sum]

This is the value to make zero on the addition of the lower 8 bits from the header to the checksum.

[Connection ID]

Random value from 0 to 255 (This value is attached to the reply data).

NOTE • Operation cannot be guaranteed when the projector receives an undened command or data.

• Provide an interval of at least 40ms between the response code and any other

code.

• Commands are not accepted during warm-up.