Chapter 9 PGL Command Set Standards
Printa ble Data De limiter
All printable data (excluding overlay data), alphanumeric chara cters, and
barcode data must be enclosed by a printable data delimiter. This delimiter is
always a printable character that the printer recognizes, telling it t o print the
data that follows until it encounters the same character again. Any printable
character may be used except the SFCC or the slash (/). The same printable
character must be used at both ends of the printable data. The position of the
printable data delimiter in the command format and in any examples in this
manual will be indicated by a .
NOTE: Only characters that do not appear in the printable data field can b e
used as delimiters.
Spaces
Do not use spaces between the command parameters unless speci fically
required.
Command Parameters
The majority of the PGL commands have multiple comma nd parameters.
Some parameters are required and some are optional. There are sev eral
selections you may enter for some of the required parameter s (for example,
SFCC). These parameters must be separated by a semicolon.
Form And Logo Names
Names identifying forms or logos may be no longer than eight charac ters. The
document name is used in the EXECUTE Form Mode to ide ntify the form or in
CREATE Form Mode to identify the logo to be used for printing.
NOTE: Do not use spaces in the document name.
The following characters may be used in document names.
Upper and lower-case A-Z (HEX 41-5A and 61-7A).
Number 0-9 (HEX 30-39)
Dollar Sign ($) (HEX 24)
Percent Sign (%) (HEX 25)
Dash (-) (HEX 2D)
At Sign (@) (HEX 40)
Braces { } (HEX 7B and 7D)
Parenthesis ( ) (HEX 28 and 29)
Tilde (~) (HEX 7E)
Single Quotes (‘ ‘) (HEX 60 and 27)
Exclamation Point (!) (HEX 21)
Pound Sign (#) (HEX 23)