Horizontal And Vertical Line Commands (Create)
195
Vertical Line Command
STOP Command Terminator. Enter STOP and the printer waits for a new
command. Leave STOP out and the
printer will wait for another Horizontal Line
Command.
Table 29. Horizontal Line Command
Field Function Option/Modifier Selections
Tabl e 30. Vertical Line Command
Field Function Option/Modifier Selections
VERT Command Specifier. Enter VERT
The following parameters define print location and line thic kness of a vertical line. The SR, SC,
and EC parameters control placement, length, and thicknes s of vertical lines on a form. Whether
in columns or dots depends on the SCALE Command. You may also use the XX.YY format for
plotting duplication print locations explained earlier in the Standards Section.
LT; Dictates the line thickness. Vertical line thickness is based on dot
increments (1/60”), then end the entry with
the parameter delimiter. Line thickness is
only limited by specifications.
SC; Plots the starting COLUMN of the
line.
Enter a value ranging from 1 to one less
than the maximum form width and the
parameter delimiter.
SR; Plots the starting ROW of the line. Enter a value ranging from 1 to one less
than the maximum form length and the
parameter delimiter.
ER Plots the ending ROW of the line. Enter a value ranging from 2 to one less
than the maximum form length.
STOP Command Terminator. Enter STOP and the printer waits for a new
command. Leave STOP out and the
printer will wait for another Vertical Line
Command.