Valid Control Sequences

(size)

Scale factor affecting both height and unit width of

 

the bars, ranging from 1-8 (default = 1).

(option)

Human Readable Characters option (default = 1)

1 = No characters

2 = Data Processing font

3= OCR-A font

4= OCR-B font

^C - Select Vertical Barcode

Selects Vertical Barcode and sets barcode parameters. Type, height, and size parameters and options are the same as for Horizontal Barcode. Defaults are the same as for horizontal (type = 1, height = 80, size = 1).

Command ^C(type);(height);(size)NL

^D - Select Double Density Block Characters

Selects 120 dots per inch and sets Block Character parameters.

Command ^D(height);(width)NL

Argument

(height)

Character Height = 0.12 inches x height multiplier

 

or

 

Height Multiplier = Character Height/0.12.

 

Line feed distance = Unit line x height multiplier,

 

(Unit line = unit line height set by ^U control

 

sequence).

(width)

Character width multiplier in the range 2-125

 

(default = 2). This also affects character cell width.

 

For example:

 

Character Width = 0.08 inches x Width multiplier

 

or

 

Width Multiplier = Character Width/0.08.

 

Character Cell Width = 0.10 inches x Width

 

multiplier

 

or

 

Width multiplier = Character cell Width/0.10.