Barcode Header

L = EAN 13 without HRI

M = MSI/modified Plessey

N = UPC A with HRI

O = UPC A without HRI

P = UPC E with HRI

Q = UPC E without HRI

R = Delta Distance (IBM)

S = Code 128

T = EAN 128

All commercial barcodes (for labeling systems) of the H, I, K, L, N, O, P, Q Types can be extended using the barcodes Add-On 2 or Add-On 5

(see “Add-On Barcodes” on page 257).

HRI

HRI = Human Readable Index

HRI characters are centered if enough space is left. If the barcode printout is smaller than the HRI character field, smaller character density (CPI) is used. Start and stop codes are not printed as HRI; a space character (SP) will be stored.

Barcode Width

By specifying an ASCII value from 0 to 3, the barcode width can be defined. This allows adaption to the scanner specifications, particularly for long-range scanners.

Table 1

Header

Normal

 

 

Compressed1)

 

 

older printer

 

older printer

 

Para-

 

 

 

meter

 

types

 

types

 

 

 

(e.g.MT230)

 

(e.g.MT230)

Width of

x = 0 0.53 mm

0.54 mm

0.48 mm

0.32 mm

0.33 mm 0.27 mm 3)

x = 1 0.74 mm

0.67 mm

0.69 mm

0.53 mm

0.43 mm 0.37 mm 3)

the

x = 2 1.16 mm

1.09 mm

1.16 mm

0.74 mm

0.65 mm 0.59 mm 3)

narrow bar

x = 3 1.38 mm

1.30 mm

1.33 mm

0.95 mm

0.88 mm 0.90 mm 3)

Width of

y = 0 0.53 mm

0.54 mm

0.48 mm

0.32 mm

0.33 mm 0.27 mm 3)

the

y = 1 0.74 mm

0.67 mm

0.69 mm

0.53 mm

0.43 mm 0.37 mm 3)

narrow

y = 2 1.16 mm

1.09 mm

1.16 mm

0.74 mm

0.65 mm 0.59 mm 3)

space

y = 3 1.38 mm

1.30 mm

1.33 mm

0.95 mm

0.88 mm 0.90 mm 3)

Enlarge-

z = 0

 

2.0 : 1

 

2.0 : 1 2)

z = 1

 

2.5 : 1

 

2.5 : 1 2)

ment

z = 2

 

3.0 : 1

 

3.0 : 1 2)

factor

z = 3

 

3.5 : 1

 

3.5 : 1 2)

233

Page 233
Image 233
Tally Genicom 6600 manual Hri, Barcode Width