Chapter 7 Control Sequences

^W - Set Barcode Density

Sets the print densities and dot-making rules for Barcode printing thereby affecting print speed, symbol length, and readability through white:black and wide:narrow ratios.

For typical applications, the default values produce fully readable Barcode; however, a range of settings is provided to accomodate softer papers or drier ribbons, and to optimize size or throughput for special applications.

Command ^W (unit width);(centers);(dots)NL

Arguments

(unit width)

Unit bar or space width in 600th inch increments

 

(400th if dots = 3). Range 9 to 13 default = 11.

(centers)

Center-to-center dot spacing along the length of the

 

bars in 600th inch increments. Range 4 to 10,

 

default = 5.

(dots)

Number of dots per unit bar or space. Range 1 to 3,

 

default = 1.

 

When dots = 1, the bar width is one printed dot per

 

Barcode unit width. The bar-to-bar space is one

 

unprinted dot per unit width.

 

When dots = 2, the number of dots for an N wide

 

bar is 2N1. An N wide space is 2N + 1.

 

When dots = 3, the number of dots for an N wide

 

bar is 3N1. An N wide space is 3N+1.

 

Printing speed is directly proportional to the values

 

of unit width and centers, and print speed is half as

 

great for dots = 2 or 3 as for dots = 1. The default

 

print speed is 36 inches per minute.

128

Page 128
Image 128
Tally Genicom 6600 manual Set Barcode Density