Barcode Header

The default parameter values are the following:

Unsecured mode (see section "Secured/Unsecured mode")

HRI OFF, Normal Print, Double Pass (F = SP)

Barcode Type 2/5 matrix (a = "A")

Barcode height 1/6 inch (n = "1")

Narrow bar (x = "0")

Narrow space (y = "0")

Ratio of wide to narrow 2 to 1 (z = "0")

When only parts of the header are to be changed, copy the header up to the parameter which must be changed, and then close the header with the end- of-header character. If a header error was detected the total previous features are still active.

The "Barcode brackets" (hex.14, dec.20), initiate and terminate the printing of the barcodes.

If the printer is switched OFFLINE, all defined barcodes are printed out completely.

NOTE: The barcode remains resident in the background and can be activated again by the barcode bracket. Text justification and centering are both permitted. With activated barcodes these functions are not carried out, since they lead to conflicts with the barcodes.

Transparent Barcode/LCP Commands

Following control codes in Barcode strings can be substituted by the appropriate MTPL sequences (see “Special Features” on page 227).

Table 44. MTPL Sequences Barcode Strings Substitution

Control Code

ANSI Sequence (CSI = Hex 9B or ESC [ )

 

 

 

 

SUB

CSI 26 Space s

 

 

EM

CSI 25 Space s

 

 

DC4

CSI 20 Space s

 

 

DLE

CSI 16 Space s

 

 

SI

CSI 15 Space s

 

 

MTPL sequences without matching parameters will be ignored.

These sequences may only be used with activated barcodes.

231

Page 231
Image 231
Tally Genicom 6600 manual Transparent Barcode/LCP Commands, Barcode Header