Straight 2 of 5 Industrial (three-bar start/stop)

Default All Straight 2 of 5 Industrial Settings

Straight 2 of 5 Industrial On/Off

On

* Off

Straight 2 of 5 Industrial Redundancy

If you are encountering errors when reading Straight 2 of 5 Industrial bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redun- dancy, scan the Straight 2 of 5 Industrial Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0.

Straight 2 of 5 Industrial

Redundancy

Straight 2 of 5 Industrial Message Length

Scan the bar codes below to change the message length. Refer to Message Length Description (page 9-1)for additional

information. Minimum and Maximum lengths = 1-80. Minimum Default = 6, Maximum Default = 80.

Minimum Message Length

Maximum Message Length

9 - 13

Page 143
Image 143
Honeywell 2700 manual Straight 2 of 5 Industrial three-bar start/stop, Straight 2 of 5 Industrial On/Off