UPC-E0 Number System

The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can

be programmed so it will not transmit it. To prevent transmission, scan Off. Default = Off.

On

* Off

UPC-E0 Addenda

This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda.

2 Digit Addenda On

* 2 Digit Addenda Off

5 Digit Addenda On

* 5 Digit Addenda Off

UPC-E0 Redundancy

If you are encountering errors when reading UPC-E0 bar codes, you may want to adjust the redundancy count. Redun- dancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors. Note that the higher the redundancy count, the longer it will take to decode the bar code. To adjust the redundancy, scan the UPC-E0 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart

9 - 39

Page 169
Image 169